Intended use and safe-use principles
MIV TMJ supports professional assessment of the temporomandibular joints based on CBCT data in DICOM format. The system automatically identifies selected anatomical landmarks, defines reference planes, generates measurements and prepares a graphical report.
User
Dentist, physician or another professional user authorized by MIV P.S.A.
Input data
Complete and valid CBCT image data saved as a DICOM series or as a supported single .dcm file.
Output
Angular and linear measurements, visualization of structures, and a report supporting professional assessment.
Basic rules
- The system does not replace patient examination, medical history, medical records or the clinician's independent clinical judgment.
- Do not use the output as the sole basis for diagnosis or a treatment decision.
- Before approval, always check CBCT quality, correct right/left orientation and landmark positions in more than one plane.
- If the image is incomplete, distorted, contains strong artifacts or does not allow structures to be identified reliably, do not finalize the analysis.
- Do not use the system in emergencies or situations requiring immediate intervention.
Functions using AI / ML
MIV TMJ uses artificial intelligence and machine-learning algorithms (AI/ML) at selected stages of CBCT processing. These functions primarily include segmentation of selected structures and automated detection of predefined anatomical landmarks. Based on these outputs, the system constructs geometric elements and calculates selected TMJ parameters.
AI supports analysis - it does not replace user verification
Automatically generated outputs may be incorrect, especially when image quality is limited, anatomy is atypical, artifacts are present, or data fall outside the validated range. Before accepting an analysis, the user must verify segmentation, anatomical landmark positions, reference planes and the resulting measurements against the source CBCT image.
AI/ML models used in the production version operate in inference mode. They do not automatically learn from patient data during routine use, and an individual examination does not change model parameters for subsequent analyses.
Account creation, login and the MIV TMJ web panel
The web application is used for user registration and login, completion of account and company data, purchase and management of the license, and download of the Desktop application installer. Logging in to the web panel alone does not activate access to the Desktop system. Before purchasing a license, complete and save USER DATA and COMPANY DATA. Do not enter patient data in these forms.
Create an account
Select SIGN UP, enter the required information and accept the terms.
Sign in
Enter your credentials and confirm access using the code sent to your e-mail address.
Complete USER DATA
Enter first name, last name and phone number, then select SAVE.
Complete COMPANY DATA
Enter complete invoice details in the Invoice Data form and save them.
Order a license
In License, select ORDER LICENSE, verify invoice data and continue.
Make payment
Select an available method in the secure payment form and pay for the license.
Download the application
In Download the app, choose WINDOWS or MAC OS.
Start the system
An account with an active license is required to use the Desktop application.
Creating an account
- On the
Sign in to continuescreen, selectSIGN UP. - In
Username, enter a username containing at least 3 characters and no@sign. - Enter an active e-mail address that you can access. It will be used, among other things, for verification codes and password recovery.
- Create a password containing at least 8 characters, including an uppercase letter, lowercase letter, digit and special character.
- Re-enter the password in
Confirm Password. - Open and read
Terms and Conditions, then select the acceptance checkbox. - Select
CREATE ACCOUNT. If a verification screen appears, follow the instructions sent to the specified e-mail address.
The e-mail address must be valid
An incorrect or inaccessible e-mail address will prevent receipt of login codes and password recovery. Do not create another account to bypass the problem. Contact support first to avoid splitting licenses and data across multiple profiles.
Login and verification code
- On the login screen, enter your e-mail address or username and password.
- Select
SIGN IN. - The system sends a six-digit verification code to the e-mail address. The code has a limited validity period indicated in the system message.
- Enter the code in
Verification Codeand selectVERIFY. - If the code does not arrive, check the Spam folder and verify the address. Then use
RESEND CODE.BACK TO LOGINreturns to the login screen.
Protect your password and verification code
Do not disclose your password or verification code to anyone, including technical support. Enter the code only on the official MIV TMJ website. If you receive a code without attempting to log in, do not use it; change your password or contact support.
First account setup - required sequence
After your first successful login, complete the following steps in order. Logging in only gives access to the web panel; it does not activate a license.
- Select
USER DATA. - Check the e-mail address assigned to the account and complete
First Name,Last NameandPhone. - Select
SAVEand make sure the data have been saved. - Select
COMPANY DATA. TheInvoice Dataform opens. - Complete billing data:
Company Name,Street,Apartment Number,Post Code,CityandTax number, then selectSave. - Return to the main panel and select
ORDER LICENSEin theLicensesection. - The system displays an
Invoice Datasummary. Verify the data. If correct, selectContinue; to correct them, return toCOMPANY DATA. - You will be redirected to a secure payment page. Choose one of the currently available payment methods and complete the transaction.
- After payment has been correctly posted/activated, verify in the panel that the license is active.
- Download the correct installer from
Download the appand start the Desktop application.
A license is required to use the Desktop application
The installer may be available for download from the panel, but downloading and installing the program does not provide active access to the system functions. An account with a correctly activated license is required to use MIV TMJ Desktop. If payment has been made but the license is not shown as active, do not automatically repeat the payment. Refresh the panel, sign in again and contact support if necessary.
Payment
After billing details are approved, the system redirects the user to a secure payment service handled by Stripe. Available methods may include BLIK, Card and Apple Pay. Availability may depend on country, device and the payment operator's current configuration. Before confirming payment, check the price, license period, e-mail address and billing details.
Panel after login
| Element | Function |
|---|---|
License | Shows license status. If no license has been purchased, ORDER LICENSE is available. After purchase, the panel shows the active license and validity period; renewal may be available under the current licensing model. |
Download the app | Downloads the installer for WINDOWS or MAC OS. The installer may be available before purchase, but use of the Desktop application requires an active license. |
USER DATA | Completes user data: first name, last name and phone number. The e-mail address identifies the account. Save the data with SAVE before purchasing a license. |
COMPANY DATA | Opens the Invoice Data form. Enter complete company billing details and tax number, then select Save. These details are used in the license purchase process. |
LOG OUT | Ends the web-panel session. Use it after working on any shared device. |
Deleting an account or company data
Use Delete account and Delete company only deliberately, after confirming the correct account and securing documents that must be retained. Before deleting an account, download required reports and documents in accordance with the facility's retention policy.
Resetting a forgotten password
- On the login screen, select
FORGOT PASSWORD?. - Enter the e-mail address assigned to the account.
- Select
SEND RESET CODE. - Receive the message and enter the code only in the official reset form.
- Set a new password that meets the requirements displayed by the system and save the change.
- Return to login using
BACK TO LOGINand sign in with the new password.
If the message does not arrive, check Spam, verify the address and wait a few minutes. Do not submit multiple requests in a short period. If access still cannot be restored, contact support without sending the previous password or received code.
Starting the Desktop application and main interface elements
Desktop application installation
After downloading the installer from the web panel, use the procedure appropriate for your operating system. After installation, an MIV TMJ account with an active license is required to use the application.
Microsoft Windows - EXE installer
- Download the MIV TMJ installer for Windows from
Download the app. - Run the downloaded
.exefile. The standard installation wizard opens. - Select the installer language.
- Select the installation location or keep the default location.
- Choose whether the installer should create an MIV TMJ desktop shortcut.
- Follow the wizard and start installation.
- When installation is complete, close the wizard and start MIV TMJ from the system menu or the created shortcut.
Apple macOS - DMG disk image
- Download the MIV TMJ installer for macOS from
Download the app. - Open the downloaded
.dmgfile. - Follow the standard macOS application installation procedure displayed by the system.
- If macOS displays a security message, verify that the installer was downloaded from the official MIV TMJ panel.
- After installation, start MIV TMJ from the
Applicationsfolder.
Install only files downloaded from the official MIV TMJ panel
Do not run installers obtained from unknown sources or modified by third parties. If the installer does not start correctly, do not manually change security settings without verifying the source; contact MIV P.S.A. support.
Starting and logging in to the Desktop application
- Start the installed
MIV Desktopapplication. - Enter the e-mail address assigned to your account and the password.
- Select the login button. An Internet connection may be required on first launch or during periodic license checks.
- When work is complete, use
Logout, especially on a computer accessible to more than one person.
Active license before starting work
Before using the Desktop application, make sure user and company data are saved in the web account, license payment is complete and the license status is active. Downloading or installing the application does not itself mean the license has been activated.
Recommended working environment
Use a desktop or laptop computer that meets the requirements supplied with the current application release. A sufficiently large monitor, controlled workstation lighting and a mouse are recommended for precise landmark review. Do not install the program on an unsecured, infected or shared device without access control.
Main menu
| Menu item | Purpose |
|---|---|
Dashboard | Examination list, patient search, creation of a new examination and opening reports. |
License | Checks the expiration date of the active license. |
Product Info | Product identification, manufacturer, UDI, serial number, eIFU and marking applicable to the release. |
User Manual | Opens the available user documentation. |
Privacy policy / Terms and Conditions | Current legal information and rules for system use. |
Examination list - Dashboard
After login, the application displays the List of examinations. Each row represents one examination and includes an examination identifier, patient data, date and a link to the report.

| Element | Function |
|---|---|
Search patients | Filters the examination list. Search using data visible in the table. |
+ New Examination | Starts creation of a new examination with the current date and time. |
| Turquoise button next to a field | Allows the corresponding patient field to be changed if the function is active for the record. |
View | Opens the saved examination report. |
Minimize patient data
If full identifying data are not required, use an anonymous value or pseudonym in accordance with the facility procedure. Before starting, make sure the selected record corresponds to the correct patient and the correct CBCT examination.
Creating a new examination, DICOM data and scan-quality control
- On the Dashboard, select
+ New Examination. - In
Planes, select the planes to be displayed. - In
Points, select anatomical landmarks. All items are selected by default. - Select the series folder using
Select DICOM Directoryor a supported single file usingSelect DICOM File (.dcm). - Check the selected source name next to
Selected file, then selectPreview algorithm.

Reference planes
| Abbreviation | Interface name | Meaning in the report |
|---|---|---|
| FP | Frankfurt plane | Frankfurt plane; in slope results it may be presented as FP (SCI). |
| CP | Camper plane | Camper plane. |
| AOP | Axio Orbital Plane | Axio-orbital plane. |
Anatomical landmark glossary used when creating an examination
| Abbreviation | Interface name | Working description |
|---|---|---|
| RP / LP | Right / Left Porion | Right / left Porion landmark. |
| IR / IL | Infraorbital Right / Left | Right / left infraorbital landmark. |
| S | Subnasal | Subnasal landmark. |
| Or R / Or L | Orbitale Right / Left | Right / left Orbitale landmark. |
| RFo / LFo | Right / Left Fossa | Right / left articular fossa landmark. |
| RHA / LHA | Hinge-joint axis Right / Left | Right / left hinge-axis landmark. |
| RTS / LTS | Summit of the right / left articular tubercle | Summit of the right / left articular tubercle. |
Preparing CBCT data before import
Before importing the examination, export the CBCT dataset from the scanner software in DICOM format while preserving the complete imaging volume required for the intended analysis.
Orientation and resolution
- export the examination in AXIAL orientation;
- use the highest available spatial resolution appropriate for the examination;
- a voxel size of 0.125 mm is preferred where available in the scanner software.
Export format
- a series of consecutive DICOM
.dcmfiles belonging to the same series is preferred; - if the scanner software does not allow this type of export, a supported single multi-frame DICOM file containing the complete sequence of slices may be used.
Verify export completeness
The dataset should contain the complete sequence of slices covering the anatomical structures required for the analysis, including both temporomandibular joints when bilateral assessment is intended. Do not import an incomplete stack. Do not manually change file order or DICOM orientation or geometry metadata.
A single .dcm file is suitable only when it contains the complete CBCT volume. A single-image DICOM file is not equivalent to a complete examination.
DICOM directory or single file?
Select DICOM Directory
Use for a standard series consisting of multiple files. Select the directory that contains the correct DICOM files from the same series - not a ZIP archive and not a parent directory if the actual files are stored deeper.
Select DICOM File (.dcm)
Use when the complete examination data are stored in one supported .dcm file. The file extension alone does not confirm that the file contains a complete CBCT volume.
Before running the algorithm
- confirm that the series is complete and comes from a single examination;
- check that the field of view includes the required structures and both TMJs;
- do not manually change file order or orientation metadata;
- do not close the application while data are being loaded or calculations are running.
Segmentation, analysis and scan-quality warning
After selecting DICOM data and starting Preview algorithm, the system processes the examination, including segmentation and analysis required to prepare the review view. If the system detects potential inconsistencies or input-data limitations, WARNING - SCAN QUALITY is displayed before image, plane and landmark verification.

WARNING - SCAN QUALITY
The message means that the system detected potential issues in the input data. These may relate to patient positioning, field of view (FOV) or visibility of anatomical structures required for reliable analysis. Generated results may therefore be incomplete or inaccurate. Before continuing, a qualified user should independently verify CBCT quality and suitability for the intended analysis.
| Message element | Meaning and required action |
|---|---|
I confirm that I have verified... | Select the checkbox only after actually checking image quality, field of view and visibility of required structures, and after understanding the result limitations. Selecting the checkbox does not confirm that the examination is correct. |
Read the full disclaimer and limitation of liability | Opens the full information on system limitations and interpretation of results. |
Cancel | Stops progression to the next analysis stage when the data are unsuitable or the user cannot reliably confirm their quality. |
Continue | Becomes available after confirmation is selected. Allows progression to image, plane and landmark verification, but does not remove the detected limitations and does not mean that the system has accepted the examination as correct. |
Small field of view (FOV)
A small FOV does not automatically exclude assessment of visible TMJ anatomy. However, if the scan does not allow verification of mandibular position relative to the maxilla and the patient's occlusion during acquisition, the visible anatomy may be assessed but interpretation of topographic relationships should be appropriately limited.
If data are technically corrupted, incomplete or unsupported in a way that prevents analysis, the system may block the process rather than allow continuation through the warning.
Verification of image, AI outputs, planes and landmarks
After analysis is complete - and, if WARNING - SCAN QUALITY was displayed, after the user has completed the required review and consciously selected how to proceed - the system presents 2D slices, a 3D model, reference planes and automatically detected landmarks. This is a separate control stage: the scan-quality warning does not replace anatomical verification of landmarks, segmentation and planes.

Image controls
| Input | Mode | Action |
|---|---|---|
| Left mouse button | Contrast | Adjusts the image display window. |
| Left mouse button | Edit | Selects and manually moves anatomical landmarks. |
| Left mouse button | Ruler | Auxiliary distance measurement. |
| Left mouse button | Protractor | Auxiliary angle measurement. |
| Mouse wheel | Scroll | Moves through image slices. |
| Mouse wheel | Zoom | Zooms in and out. |
| Right mouse button | Pan | Moves the image within the viewport. |
| Right mouse button | Rotate | Rotates the view where available. |
View controls
LevelandWidth- display-window level and width. They change image presentation, not patient anatomy.Axial,Coronal,Sagittal- select a slice in the corresponding plane.Roll,Pitch,Yaw- control spatial orientation.Point SizeandFilled Points- control landmark-marker appearance.Reset- restores view settings to their initial values.- Checkboxes in
Planesshow or hide individual reference planes. Go tonext to a landmark positions the view in its vicinity and facilitates verification.
How to verify a landmark
- Select
Go tonext to the landmark. - Check its position in at least two perpendicular 2D views.
- Confirm that the marker lies on the correct structure and not on an artifact, adjacent-bone edge or unrelated slice.
- Compare the right and left sides and R/L labels with the source-data orientation.
Manual correction of an anatomical landmark
- Navigate to the landmark using
Go to. - Select
Editmode. - Move the landmark to the correct structure in the 2D view.
- Check the new position in the remaining planes.
- Read the manual-modification message and select the appropriate action.

| Button | Effect |
|---|---|
Read the full disclaimer and limitation of liability | Opens full information on the implications of manual modification. |
Discard | Rejects the initiated change and does not accept the manually modified result. |
Accept | Accepts the modification. Subsequent results are treated as being based in part on manual user intervention. |
Responsibility for a manual change
After manual correction, angle, plane and distance values depend on the user's decision. The examination status may show Manual landmark adjustment in progress. Accept a change only when the landmark position can be clearly justified anatomically. Do not move a landmark solely to obtain an expected measurement value.
Reviewing measurement results
The result screen displays the right and left sides separately, TMJ views, a reference section and measurement tables. Before finalization, compare the numerical values with the visible geometry and marker positions.

What the tables contain
Measurement of the TMJ Slope
Inclination angles referenced to CP, AOP and FP (SCI), presented in degrees separately for the right and left sides.
Measurement of the TMJ Joint Space
Distances in millimetres: anterior A1-A2, posterior B1-B2, superior Apex-C, medial M1-M2 and lateral L1-L2.
Draft-result controls
| Element | User meaning |
|---|---|
View: Preview | Shows the current preview before final approval. |
View: Committed | Shows the last committed result version. |
Commit | Commits the current settings and measurements. |
Re-run | Runs calculations again for the current settings. |
Run from view (R/L) | Runs the calculation for the corresponding side using the current view settings. |
Run from apex (R/L) | Runs the calculation for the corresponding side from the selected Apex point when the option is active. |
Extend to median | Extends the reference-line display to the midline. |
Back to Preview | Returns to image and landmark verification. |
Finalize Report | Finalizes the result and proceeds to the report. |
The result is not a diagnosis
A difference between the right and left sides, or any single value, does not automatically establish pathology. Results must be interpreted together with the complete CBCT image, symptoms, clinical examination, data quality and method limitations.
Report, finalization and export
The TMJ Algorithm Report combines examination data, right- and left-side measurements and reference images. Depending on the release, it includes a reference section and sagittal and coronal images of both TMJs with landmarks.

- Check the examination identifier, date and - if used - patient data.
- Compare
Right SideandLeft Sidelabels with the examination orientation. - Check completeness of tables and images:
Reference Section,Right/Left SagittalandRight/Left Coronal. - If an error is identified, select
Back to Previewand return to verification. - Select
Export Report, then save the file in a location intended for medical documentation. - Before adding the report to documentation, open the exported file and confirm that it is complete and readable.
Secure storage
Do not save a report containing patient data in a random folder, public cloud location or shared Desktop. Use the storage location and retention rules adopted by the facility. Back to List returns to the examination list without requiring export.
License and product information
License
The web panel is used to purchase, check and renew the license. If the account has no active license, select ORDER LICENSE. Correct USER DATA and COMPANY DATA must be saved before payment. An active license is required to use the Desktop application.
Product Info
The product-identification screen may contain UDI, SN, medical-device status, CE marking where applicable to the release, issue/production date, an eIFU link and manufacturer information for MIV P.S.A.
Purchasing and activating a license
- Log in to the MIV TMJ web panel.
- Complete and save
USER DATA. - Complete and save
COMPANY DATA/Invoice Data. - In
License, selectORDER LICENSE. - Verify the displayed invoice details and select
Continue. - On the payment page, check the price and license period, select an available payment method and approve the transaction.
- After returning to the panel, check the active license status before starting the Desktop application.
Do not repeat payment before checking status
If payment has been approved by the operator but the license is not yet displayed as active, refresh the panel or sign in again. If the status still does not change, contact support and provide the account e-mail address and transaction information - without sending card data, BLIK codes or other authentication data.
Patient data, privacy and security
- Enter only the data necessary to perform the examination and maintain documentation.
- If allowed by the facility procedure, anonymize or pseudonymize data before import.
- Make sure the facility has an appropriate legal basis for processing health data.
- Protect the password and verification codes, lock the workstation when leaving it, and do not share the account or active session with other persons.
- Do not send complete DICOM data, reports or screenshots containing patient data to support without an agreed secure procedure.
- Use an up-to-date operating system, security software and the current version of MIV TMJ.
- After work, select
LOG OUTin the web panel andLogoutin the Desktop application.
Current rules for data processing and use of the system are available in the Privacy Policy and Terms and Conditions.
Troubleshooting
I cannot sign in to the web panel
Check that you are entering the correct e-mail address or username and that Caps Lock is not enabled. Do not disclose your password to other persons. If the password is unknown, use FORGOT PASSWORD? instead of creating another account.
The verification code does not arrive or has expired
Check Spam and verify the e-mail address, wait a few minutes, then use RESEND CODE. Enter the most recently received code. The code has a limited validity period indicated in the system message. If the problem persists, return using BACK TO LOGIN and contact support without sending the code or password.
I do not receive the password-reset code
Make sure the Forgot Password form contains exactly the e-mail address assigned to the account. Check Spam and do not submit many requests one after another. If the message still does not arrive, contact support@mivtmj.com. Do not create a second account or send the current password.
The “Preview algorithm” button remains inactive
Check that a DICOM directory or file has been selected and that a source name is displayed next to Selected file. Do not select a ZIP archive. For a multi-file series, select the directory containing the actual files rather than an empty parent directory.
The DICOM series does not load or only one slice is visible
Confirm that all files belong to one series and that the CBCT export is complete. If the examination is stored in multiple files, use Select DICOM Directory. If one file is expected to contain the complete volume, check in a DICOM viewer that it is a valid multi-frame object rather than a single image.
“WARNING - SCAN QUALITY” is displayed
Do not treat the message as an application error. The system is indicating potential input-data limitations, for example patient positioning, FOV or visibility of required structures. Review the CBCT before continuing. If you cannot confirm its suitability for the intended analysis, select Cancel. If, after review, you consciously continue, select the required confirmation and Continue. Continuing does not remove the data limitations and does not replace later verification of segmentation, landmarks, planes and results.
The image is inverted or right/left orientation is uncertain
Do not correct sides based only on appearance. Compare orientation labels and DICOM metadata with the source CBCT software. If orientation remains ambiguous, stop the analysis and verify the export.
A landmark or plane is not visible
Check that the item is selected in Reference Points or Planes. Use Go to, increase Point Size and navigate to the appropriate slice. If required, use Reset for view settings.
An automatically generated landmark looks incorrect
Assess source quality, artifacts and the landmark in at least two planes. If the structure can be identified reliably, make a deliberate correction in Edit mode and review the warning. If the structure cannot be identified reliably, do not finalize the result.
Results after correction differ from the automatic result
This is expected because angles and distances depend on landmark positions. Compare Preview with Committed, verify every changed landmark and use Commit only after the review is complete.
The report cannot be exported
Check write permissions in the selected directory, available disk space and whether a file with the same name is already open. Try saving the report in an approved local directory. If the issue repeats, record the examination identifier and application version, then contact support without sending patient data over an unprotected channel.
I cannot order or pay for a license
First check that complete user data are saved in USER DATA and complete Invoice Data, including the tax number, are saved in COMPANY DATA. Return to License and select ORDER LICENSE again. Verify the invoice summary before proceeding to the payment operator. If the payment form does not open or payment cannot be completed, do not create another account; contact support.
The license has expired or is not recognized
Check the Internet connection and date in License. Restart the application. If the problem persists, contact support@mivtmj.com.
Finalization checklist and support
- The correct patient and the correct CBCT examination have been selected.
- DICOM data are complete, readable and include the required structures.
- If
WARNING - SCAN QUALITYwas displayed, image quality, FOV and visibility of required structures were reviewed and a deliberate decision was made on how to proceed. - Right and left orientation labels have been verified.
- All planes and landmarks used in the analysis have been checked.
- Each key landmark has been reviewed in at least two 2D views.
- All manual corrections have been consciously verified and accepted.
- Table values are consistent with the visible geometry and do not raise quality concerns.
- Header data and report completeness have been checked.
- The exported file opens correctly and has been saved in a secure location.
Technical support
E-mail: support@mivtmj.com
General information: info@mivtmj.com
Website: mivtmj.com
When reporting an issue, provide the application version, operating system, work stage, message text and examination identifier. Do not attach personal or medical data unless a secure transfer method has been agreed.