User Manual • Web and Desktop application • EN

MIV TMJ — step-by-step user manual

How to create an account, sign in to the web panel, download the application, create an examination, import CBCT DICOM data, complete scan-quality control, verify anatomical landmarks and export a report.

Version 1.6 Updated: 21.09.2026 For professional users

Important before use

This manual describes how to use the current production version of MIV TMJ. The system is intended for qualified professional users and supports assessment of selected temporomandibular-joint parameters based on CBCT DICOM data. MIV TMJ does not provide an autonomous diagnosis and does not replace patient examination, medical history or the clinician’s independent clinical judgment. All automatically generated results require user verification before they are used in clinical assessment.

1Create an account and sign in
2Complete USER DATA and COMPANY DATA
3Order and pay for a license
4Download and start the Desktop application
5Load DICOM, run the analysis and verify the result
6Review measurements and export the report
Chapter 01

Intended use and safe-use principles

MIV TMJ supports professional assessment of the temporomandibular joints based on CBCT data in DICOM format. The system automatically identifies selected anatomical landmarks, defines reference planes, generates measurements and prepares a graphical report.

User

Dentist, physician or another professional user authorized by MIV P.S.A.

Input data

Complete and valid CBCT image data saved as a DICOM series or as a supported single .dcm file.

Output

Angular and linear measurements, visualization of structures, and a report supporting professional assessment.

Basic rules

  • The system does not replace patient examination, medical history, medical records or the clinician's independent clinical judgment.
  • Do not use the output as the sole basis for diagnosis or a treatment decision.
  • Before approval, always check CBCT quality, correct right/left orientation and landmark positions in more than one plane.
  • If the image is incomplete, distorted, contains strong artifacts or does not allow structures to be identified reliably, do not finalize the analysis.
  • Do not use the system in emergencies or situations requiring immediate intervention.

Functions using AI / ML

MIV TMJ uses artificial intelligence and machine-learning algorithms (AI/ML) at selected stages of CBCT processing. These functions primarily include segmentation of selected structures and automated detection of predefined anatomical landmarks. Based on these outputs, the system constructs geometric elements and calculates selected TMJ parameters.

AI supports analysis - it does not replace user verification

Automatically generated outputs may be incorrect, especially when image quality is limited, anatomy is atypical, artifacts are present, or data fall outside the validated range. Before accepting an analysis, the user must verify segmentation, anatomical landmark positions, reference planes and the resulting measurements against the source CBCT image.

AI/ML models used in the production version operate in inference mode. They do not automatically learn from patient data during routine use, and an individual examination does not change model parameters for subsequent analyses.

Chapter 02

Account creation, login and the MIV TMJ web panel

The web application is used for user registration and login, completion of account and company data, purchase and management of the license, and download of the Desktop application installer. Logging in to the web panel alone does not activate access to the Desktop system. Before purchasing a license, complete and save USER DATA and COMPANY DATA. Do not enter patient data in these forms.

01

Create an account

Select SIGN UP, enter the required information and accept the terms.

02

Sign in

Enter your credentials and confirm access using the code sent to your e-mail address.

03

Complete USER DATA

Enter first name, last name and phone number, then select SAVE.

04

Complete COMPANY DATA

Enter complete invoice details in the Invoice Data form and save them.

05

Order a license

In License, select ORDER LICENSE, verify invoice data and continue.

06

Make payment

Select an available method in the secure payment form and pay for the license.

07

Download the application

In Download the app, choose WINDOWS or MAC OS.

08

Start the system

An account with an active license is required to use the Desktop application.

Creating an account

  1. On the Sign in to continue screen, select SIGN UP.
  2. In Username, enter a username containing at least 3 characters and no @ sign.
  3. Enter an active e-mail address that you can access. It will be used, among other things, for verification codes and password recovery.
  4. Create a password containing at least 8 characters, including an uppercase letter, lowercase letter, digit and special character.
  5. Re-enter the password in Confirm Password.
  6. Open and read Terms and Conditions, then select the acceptance checkbox.
  7. Select CREATE ACCOUNT. If a verification screen appears, follow the instructions sent to the specified e-mail address.

The e-mail address must be valid

An incorrect or inaccessible e-mail address will prevent receipt of login codes and password recovery. Do not create another account to bypass the problem. Contact support first to avoid splitting licenses and data across multiple profiles.

Login and verification code

  1. On the login screen, enter your e-mail address or username and password.
  2. Select SIGN IN.
  3. The system sends a six-digit verification code to the e-mail address. The code has a limited validity period indicated in the system message.
  4. Enter the code in Verification Code and select VERIFY.
  5. If the code does not arrive, check the Spam folder and verify the address. Then use RESEND CODE. BACK TO LOGIN returns to the login screen.

Protect your password and verification code

Do not disclose your password or verification code to anyone, including technical support. Enter the code only on the official MIV TMJ website. If you receive a code without attempting to log in, do not use it; change your password or contact support.

First account setup - required sequence

After your first successful login, complete the following steps in order. Logging in only gives access to the web panel; it does not activate a license.

  1. Select USER DATA.
  2. Check the e-mail address assigned to the account and complete First Name, Last Name and Phone.
  3. Select SAVE and make sure the data have been saved.
  4. Select COMPANY DATA. The Invoice Data form opens.
  5. Complete billing data: Company Name, Street, Apartment Number, Post Code, City and Tax number, then select Save.
  6. Return to the main panel and select ORDER LICENSE in the License section.
  7. The system displays an Invoice Data summary. Verify the data. If correct, select Continue; to correct them, return to COMPANY DATA.
  8. You will be redirected to a secure payment page. Choose one of the currently available payment methods and complete the transaction.
  9. After payment has been correctly posted/activated, verify in the panel that the license is active.
  10. Download the correct installer from Download the app and start the Desktop application.

A license is required to use the Desktop application

The installer may be available for download from the panel, but downloading and installing the program does not provide active access to the system functions. An account with a correctly activated license is required to use MIV TMJ Desktop. If payment has been made but the license is not shown as active, do not automatically repeat the payment. Refresh the panel, sign in again and contact support if necessary.

Payment

After billing details are approved, the system redirects the user to a secure payment service handled by Stripe. Available methods may include BLIK, Card and Apple Pay. Availability may depend on country, device and the payment operator's current configuration. Before confirming payment, check the price, license period, e-mail address and billing details.

Panel after login

ElementFunction
LicenseShows license status. If no license has been purchased, ORDER LICENSE is available. After purchase, the panel shows the active license and validity period; renewal may be available under the current licensing model.
Download the appDownloads the installer for WINDOWS or MAC OS. The installer may be available before purchase, but use of the Desktop application requires an active license.
USER DATACompletes user data: first name, last name and phone number. The e-mail address identifies the account. Save the data with SAVE before purchasing a license.
COMPANY DATAOpens the Invoice Data form. Enter complete company billing details and tax number, then select Save. These details are used in the license purchase process.
LOG OUTEnds the web-panel session. Use it after working on any shared device.

Deleting an account or company data

Use Delete account and Delete company only deliberately, after confirming the correct account and securing documents that must be retained. Before deleting an account, download required reports and documents in accordance with the facility's retention policy.

Resetting a forgotten password

  1. On the login screen, select FORGOT PASSWORD?.
  2. Enter the e-mail address assigned to the account.
  3. Select SEND RESET CODE.
  4. Receive the message and enter the code only in the official reset form.
  5. Set a new password that meets the requirements displayed by the system and save the change.
  6. Return to login using BACK TO LOGIN and sign in with the new password.

If the message does not arrive, check Spam, verify the address and wait a few minutes. Do not submit multiple requests in a short period. If access still cannot be restored, contact support without sending the previous password or received code.

Chapter 03

Starting the Desktop application and main interface elements

Desktop application installation

After downloading the installer from the web panel, use the procedure appropriate for your operating system. After installation, an MIV TMJ account with an active license is required to use the application.

Microsoft Windows - EXE installer

  1. Download the MIV TMJ installer for Windows from Download the app.
  2. Run the downloaded .exe file. The standard installation wizard opens.
  3. Select the installer language.
  4. Select the installation location or keep the default location.
  5. Choose whether the installer should create an MIV TMJ desktop shortcut.
  6. Follow the wizard and start installation.
  7. When installation is complete, close the wizard and start MIV TMJ from the system menu or the created shortcut.

Apple macOS - DMG disk image

  1. Download the MIV TMJ installer for macOS from Download the app.
  2. Open the downloaded .dmg file.
  3. Follow the standard macOS application installation procedure displayed by the system.
  4. If macOS displays a security message, verify that the installer was downloaded from the official MIV TMJ panel.
  5. After installation, start MIV TMJ from the Applications folder.

Install only files downloaded from the official MIV TMJ panel

Do not run installers obtained from unknown sources or modified by third parties. If the installer does not start correctly, do not manually change security settings without verifying the source; contact MIV P.S.A. support.

Starting and logging in to the Desktop application

  1. Start the installed MIV Desktop application.
  2. Enter the e-mail address assigned to your account and the password.
  3. Select the login button. An Internet connection may be required on first launch or during periodic license checks.
  4. When work is complete, use Logout, especially on a computer accessible to more than one person.

Active license before starting work

Before using the Desktop application, make sure user and company data are saved in the web account, license payment is complete and the license status is active. Downloading or installing the application does not itself mean the license has been activated.

Recommended working environment

Use a desktop or laptop computer that meets the requirements supplied with the current application release. A sufficiently large monitor, controlled workstation lighting and a mouse are recommended for precise landmark review. Do not install the program on an unsecured, infected or shared device without access control.

Main menu

Menu itemPurpose
DashboardExamination list, patient search, creation of a new examination and opening reports.
LicenseChecks the expiration date of the active license.
Product InfoProduct identification, manufacturer, UDI, serial number, eIFU and marking applicable to the release.
User ManualOpens the available user documentation.
Privacy policy / Terms and ConditionsCurrent legal information and rules for system use.
Chapter 04

Examination list - Dashboard

After login, the application displays the List of examinations. Each row represents one examination and includes an examination identifier, patient data, date and a link to the report.

MIV TMJ Dashboard with the examination list and New Examination button
Dashboard: search, examination list, editable fields and access to the report.
ElementFunction
Search patientsFilters the examination list. Search using data visible in the table.
+ New ExaminationStarts creation of a new examination with the current date and time.
Turquoise button next to a fieldAllows the corresponding patient field to be changed if the function is active for the record.
ViewOpens the saved examination report.

Minimize patient data

If full identifying data are not required, use an anonymous value or pseudonym in accordance with the facility procedure. Before starting, make sure the selected record corresponds to the correct patient and the correct CBCT examination.

Chapter 05

Creating a new examination, DICOM data and scan-quality control

  1. On the Dashboard, select + New Examination.
  2. In Planes, select the planes to be displayed.
  3. In Points, select anatomical landmarks. All items are selected by default.
  4. Select the series folder using Select DICOM Directory or a supported single file using Select DICOM File (.dcm).
  5. Check the selected source name next to Selected file, then select Preview algorithm.
MIV TMJ new examination screen with plane, landmark and DICOM selection
New examination: selection of analysis scope and DICOM data source.

Reference planes

AbbreviationInterface nameMeaning in the report
FPFrankfurt planeFrankfurt plane; in slope results it may be presented as FP (SCI).
CPCamper planeCamper plane.
AOPAxio Orbital PlaneAxio-orbital plane.

Anatomical landmark glossary used when creating an examination

AbbreviationInterface nameWorking description
RP / LPRight / Left PorionRight / left Porion landmark.
IR / ILInfraorbital Right / LeftRight / left infraorbital landmark.
SSubnasalSubnasal landmark.
Or R / Or LOrbitale Right / LeftRight / left Orbitale landmark.
RFo / LFoRight / Left FossaRight / left articular fossa landmark.
RHA / LHAHinge-joint axis Right / LeftRight / left hinge-axis landmark.
RTS / LTSSummit of the right / left articular tubercleSummit of the right / left articular tubercle.

Preparing CBCT data before import

Before importing the examination, export the CBCT dataset from the scanner software in DICOM format while preserving the complete imaging volume required for the intended analysis.

Orientation and resolution

  • export the examination in AXIAL orientation;
  • use the highest available spatial resolution appropriate for the examination;
  • a voxel size of 0.125 mm is preferred where available in the scanner software.

Export format

  • a series of consecutive DICOM .dcm files belonging to the same series is preferred;
  • if the scanner software does not allow this type of export, a supported single multi-frame DICOM file containing the complete sequence of slices may be used.

Verify export completeness

The dataset should contain the complete sequence of slices covering the anatomical structures required for the analysis, including both temporomandibular joints when bilateral assessment is intended. Do not import an incomplete stack. Do not manually change file order or DICOM orientation or geometry metadata.

A single .dcm file is suitable only when it contains the complete CBCT volume. A single-image DICOM file is not equivalent to a complete examination.

DICOM directory or single file?

Select DICOM Directory

Use for a standard series consisting of multiple files. Select the directory that contains the correct DICOM files from the same series - not a ZIP archive and not a parent directory if the actual files are stored deeper.

Select DICOM File (.dcm)

Use when the complete examination data are stored in one supported .dcm file. The file extension alone does not confirm that the file contains a complete CBCT volume.

Before running the algorithm

  • confirm that the series is complete and comes from a single examination;
  • check that the field of view includes the required structures and both TMJs;
  • do not manually change file order or orientation metadata;
  • do not close the application while data are being loaded or calculations are running.

Segmentation, analysis and scan-quality warning

After selecting DICOM data and starting Preview algorithm, the system processes the examination, including segmentation and analysis required to prepare the review view. If the system detects potential inconsistencies or input-data limitations, WARNING - SCAN QUALITY is displayed before image, plane and landmark verification.

MIV TMJ WARNING – SCAN QUALITY message indicating potential input-data limitations
Warning: potential inconsistencies or limitations in the input data. Before continuing, the user must verify image quality, FOV and visibility of the required anatomical structures.

WARNING - SCAN QUALITY

The message means that the system detected potential issues in the input data. These may relate to patient positioning, field of view (FOV) or visibility of anatomical structures required for reliable analysis. Generated results may therefore be incomplete or inaccurate. Before continuing, a qualified user should independently verify CBCT quality and suitability for the intended analysis.

Message elementMeaning and required action
I confirm that I have verified...Select the checkbox only after actually checking image quality, field of view and visibility of required structures, and after understanding the result limitations. Selecting the checkbox does not confirm that the examination is correct.
Read the full disclaimer and limitation of liabilityOpens the full information on system limitations and interpretation of results.
CancelStops progression to the next analysis stage when the data are unsuitable or the user cannot reliably confirm their quality.
ContinueBecomes available after confirmation is selected. Allows progression to image, plane and landmark verification, but does not remove the detected limitations and does not mean that the system has accepted the examination as correct.

Small field of view (FOV)

A small FOV does not automatically exclude assessment of visible TMJ anatomy. However, if the scan does not allow verification of mandibular position relative to the maxilla and the patient's occlusion during acquisition, the visible anatomy may be assessed but interpretation of topographic relationships should be appropriately limited.

If data are technically corrupted, incomplete or unsupported in a way that prevents analysis, the system may block the process rather than allow continuation through the warning.

Chapter 06

Verification of image, AI outputs, planes and landmarks

After analysis is complete - and, if WARNING - SCAN QUALITY was displayed, after the user has completed the required review and consciously selected how to proceed - the system presents 2D slices, a 3D model, reference planes and automatically detected landmarks. This is a separate control stage: the scan-quality warning does not replace anatomical verification of landmarks, segmentation and planes.

MIV TMJ 2D and 3D review view with reference planes and anatomical landmarks
Review view: 2D slices, 3D reconstruction, planes and anatomical landmark list.

Image controls

InputModeAction
Left mouse buttonContrastAdjusts the image display window.
Left mouse buttonEditSelects and manually moves anatomical landmarks.
Left mouse buttonRulerAuxiliary distance measurement.
Left mouse buttonProtractorAuxiliary angle measurement.
Mouse wheelScrollMoves through image slices.
Mouse wheelZoomZooms in and out.
Right mouse buttonPanMoves the image within the viewport.
Right mouse buttonRotateRotates the view where available.

View controls

  • Level and Width - display-window level and width. They change image presentation, not patient anatomy.
  • Axial, Coronal, Sagittal - select a slice in the corresponding plane.
  • Roll, Pitch, Yaw - control spatial orientation.
  • Point Size and Filled Points - control landmark-marker appearance.
  • Reset - restores view settings to their initial values.
  • Checkboxes in Planes show or hide individual reference planes.
  • Go to next to a landmark positions the view in its vicinity and facilitates verification.

How to verify a landmark

  1. Select Go to next to the landmark.
  2. Check its position in at least two perpendicular 2D views.
  3. Confirm that the marker lies on the correct structure and not on an artifact, adjacent-bone edge or unrelated slice.
  4. Compare the right and left sides and R/L labels with the source-data orientation.
Chapter 07

Manual correction of an anatomical landmark

  1. Navigate to the landmark using Go to.
  2. Select Edit mode.
  3. Move the landmark to the correct structure in the 2D view.
  4. Check the new position in the remaining planes.
  5. Read the manual-modification message and select the appropriate action.
MIV TMJ warning displayed after manual modification of an anatomical landmark
After a landmark is changed, the system displays a warning about manual data modification.
ButtonEffect
Read the full disclaimer and limitation of liabilityOpens full information on the implications of manual modification.
DiscardRejects the initiated change and does not accept the manually modified result.
AcceptAccepts the modification. Subsequent results are treated as being based in part on manual user intervention.

Responsibility for a manual change

After manual correction, angle, plane and distance values depend on the user's decision. The examination status may show Manual landmark adjustment in progress. Accept a change only when the landmark position can be clearly justified anatomically. Do not move a landmark solely to obtain an expected measurement value.

Chapter 08

Reviewing measurement results

The result screen displays the right and left sides separately, TMJ views, a reference section and measurement tables. Before finalization, compare the numerical values with the visible geometry and marker positions.

MIV TMJ result screen with right and left TMJ Slope and Joint Space measurements
Results preview: right and left sides, angular measurements and radiological joint spaces.

What the tables contain

Measurement of the TMJ Slope

Inclination angles referenced to CP, AOP and FP (SCI), presented in degrees separately for the right and left sides.

Measurement of the TMJ Joint Space

Distances in millimetres: anterior A1-A2, posterior B1-B2, superior Apex-C, medial M1-M2 and lateral L1-L2.

Draft-result controls

ElementUser meaning
View: PreviewShows the current preview before final approval.
View: CommittedShows the last committed result version.
CommitCommits the current settings and measurements.
Re-runRuns calculations again for the current settings.
Run from view (R/L)Runs the calculation for the corresponding side using the current view settings.
Run from apex (R/L)Runs the calculation for the corresponding side from the selected Apex point when the option is active.
Extend to medianExtends the reference-line display to the midline.
Back to PreviewReturns to image and landmark verification.
Finalize ReportFinalizes the result and proceeds to the report.

The result is not a diagnosis

A difference between the right and left sides, or any single value, does not automatically establish pathology. Results must be interpreted together with the complete CBCT image, symptoms, clinical examination, data quality and method limitations.

Chapter 09

Report, finalization and export

The TMJ Algorithm Report combines examination data, right- and left-side measurements and reference images. Depending on the release, it includes a reference section and sagittal and coronal images of both TMJs with landmarks.

MIV TMJ report with TMJ Slope measurements, Joint Space measurements and reference images
Final report: examination identification, measurements and graphical documentation.
  1. Check the examination identifier, date and - if used - patient data.
  2. Compare Right Side and Left Side labels with the examination orientation.
  3. Check completeness of tables and images: Reference Section, Right/Left Sagittal and Right/Left Coronal.
  4. If an error is identified, select Back to Preview and return to verification.
  5. Select Export Report, then save the file in a location intended for medical documentation.
  6. Before adding the report to documentation, open the exported file and confirm that it is complete and readable.

Secure storage

Do not save a report containing patient data in a random folder, public cloud location or shared Desktop. Use the storage location and retention rules adopted by the facility. Back to List returns to the examination list without requiring export.

Chapter 10

License and product information

License

The web panel is used to purchase, check and renew the license. If the account has no active license, select ORDER LICENSE. Correct USER DATA and COMPANY DATA must be saved before payment. An active license is required to use the Desktop application.

Product Info

The product-identification screen may contain UDI, SN, medical-device status, CE marking where applicable to the release, issue/production date, an eIFU link and manufacturer information for MIV P.S.A.

Purchasing and activating a license

  1. Log in to the MIV TMJ web panel.
  2. Complete and save USER DATA.
  3. Complete and save COMPANY DATA / Invoice Data.
  4. In License, select ORDER LICENSE.
  5. Verify the displayed invoice details and select Continue.
  6. On the payment page, check the price and license period, select an available payment method and approve the transaction.
  7. After returning to the panel, check the active license status before starting the Desktop application.

Do not repeat payment before checking status

If payment has been approved by the operator but the license is not yet displayed as active, refresh the panel or sign in again. If the status still does not change, contact support and provide the account e-mail address and transaction information - without sending card data, BLIK codes or other authentication data.

Chapter 11

Patient data, privacy and security

  • Enter only the data necessary to perform the examination and maintain documentation.
  • If allowed by the facility procedure, anonymize or pseudonymize data before import.
  • Make sure the facility has an appropriate legal basis for processing health data.
  • Protect the password and verification codes, lock the workstation when leaving it, and do not share the account or active session with other persons.
  • Do not send complete DICOM data, reports or screenshots containing patient data to support without an agreed secure procedure.
  • Use an up-to-date operating system, security software and the current version of MIV TMJ.
  • After work, select LOG OUT in the web panel and Logout in the Desktop application.

Current rules for data processing and use of the system are available in the Privacy Policy and Terms and Conditions.

Chapter 12

Troubleshooting

I cannot sign in to the web panel

Check that you are entering the correct e-mail address or username and that Caps Lock is not enabled. Do not disclose your password to other persons. If the password is unknown, use FORGOT PASSWORD? instead of creating another account.

The verification code does not arrive or has expired

Check Spam and verify the e-mail address, wait a few minutes, then use RESEND CODE. Enter the most recently received code. The code has a limited validity period indicated in the system message. If the problem persists, return using BACK TO LOGIN and contact support without sending the code or password.

I do not receive the password-reset code

Make sure the Forgot Password form contains exactly the e-mail address assigned to the account. Check Spam and do not submit many requests one after another. If the message still does not arrive, contact support@mivtmj.com. Do not create a second account or send the current password.

The “Preview algorithm” button remains inactive

Check that a DICOM directory or file has been selected and that a source name is displayed next to Selected file. Do not select a ZIP archive. For a multi-file series, select the directory containing the actual files rather than an empty parent directory.

The DICOM series does not load or only one slice is visible

Confirm that all files belong to one series and that the CBCT export is complete. If the examination is stored in multiple files, use Select DICOM Directory. If one file is expected to contain the complete volume, check in a DICOM viewer that it is a valid multi-frame object rather than a single image.

“WARNING - SCAN QUALITY” is displayed

Do not treat the message as an application error. The system is indicating potential input-data limitations, for example patient positioning, FOV or visibility of required structures. Review the CBCT before continuing. If you cannot confirm its suitability for the intended analysis, select Cancel. If, after review, you consciously continue, select the required confirmation and Continue. Continuing does not remove the data limitations and does not replace later verification of segmentation, landmarks, planes and results.

The image is inverted or right/left orientation is uncertain

Do not correct sides based only on appearance. Compare orientation labels and DICOM metadata with the source CBCT software. If orientation remains ambiguous, stop the analysis and verify the export.

A landmark or plane is not visible

Check that the item is selected in Reference Points or Planes. Use Go to, increase Point Size and navigate to the appropriate slice. If required, use Reset for view settings.

An automatically generated landmark looks incorrect

Assess source quality, artifacts and the landmark in at least two planes. If the structure can be identified reliably, make a deliberate correction in Edit mode and review the warning. If the structure cannot be identified reliably, do not finalize the result.

Results after correction differ from the automatic result

This is expected because angles and distances depend on landmark positions. Compare Preview with Committed, verify every changed landmark and use Commit only after the review is complete.

The report cannot be exported

Check write permissions in the selected directory, available disk space and whether a file with the same name is already open. Try saving the report in an approved local directory. If the issue repeats, record the examination identifier and application version, then contact support without sending patient data over an unprotected channel.

I cannot order or pay for a license

First check that complete user data are saved in USER DATA and complete Invoice Data, including the tax number, are saved in COMPANY DATA. Return to License and select ORDER LICENSE again. Verify the invoice summary before proceeding to the payment operator. If the payment form does not open or payment cannot be completed, do not create another account; contact support.

The license has expired or is not recognized

Check the Internet connection and date in License. Restart the application. If the problem persists, contact support@mivtmj.com.

Chapter 13

Finalization checklist and support

  • The correct patient and the correct CBCT examination have been selected.
  • DICOM data are complete, readable and include the required structures.
  • If WARNING - SCAN QUALITY was displayed, image quality, FOV and visibility of required structures were reviewed and a deliberate decision was made on how to proceed.
  • Right and left orientation labels have been verified.
  • All planes and landmarks used in the analysis have been checked.
  • Each key landmark has been reviewed in at least two 2D views.
  • All manual corrections have been consciously verified and accepted.
  • Table values are consistent with the visible geometry and do not raise quality concerns.
  • Header data and report completeness have been checked.
  • The exported file opens correctly and has been saved in a secure location.

Technical support

E-mail: support@mivtmj.com
General information: info@mivtmj.com
Website: mivtmj.com

When reporting an issue, provide the application version, operating system, work stage, message text and examination identifier. Do not attach personal or medical data unless a secure transfer method has been agreed.

MIV Prosta Spółka Akcyjna

ul. Ignacego Mościckiego 1, 24-110 Puławy, Poland

info@mivtmj.com